Optional website analytics

Allow optional website analytics, including Google Tag Manager and video play events? You can send an enquiry with either choice and change your preference in the footer. Privacy notice

Back to products

Configuration reference

1,000–3,000 MHz100 W Power class

Supply
32 V
Dimensions
158 × 122 × 25 mm

100 W-class configuration. Supplied point tests include output below 100 W. Agree frequency-point output and operating conditions before evaluation. Conditions & evidence →

WhatsApp · John

Hardware examples

Representative RF amplifier enclosure with mounting points
Different hardware examples, not matched to this configuration. Request photographs of the proposed model and revision before evaluation.

Technical overview

Frequency range
1,000–3,000 MHz
Power class
100 W
Supply
32 V
Dimensions
158 × 122 × 25 mm
Current
≤12 A @ +32 V; source condition: CW output 80 W
Output isolator
Confirm for your configuration
Supply format
RF PA module
Gain (source Max)
53±5 dB (Max)
In-band ripple (source Peak)
≤10 dB (Peak)
Input port VSWR
≤1.8
Output port VSWR
≤3
Enable control (source wording)
Customize; note: 5 V
RF input power
Confirm for your configuration
Control interface / protocol
Confirm for your configuration
Weight
1090 g

Conditions & evidence

Values below retain the source wording and qualifiers. Max gain is not a linear-gain guarantee; port VSWR is not a permitted load-mismatch rating. Enable voltage does not establish a control protocol. Working temperature does not define a thermal design. Missing fields require confirmation for this configuration.

Temperature protection (source wording)

Source declares amplifier shutdown at 80°C. Measurement point and reset logic require confirmation.

Working temperature (source wording)

−20 to +85°C; source note: working properly

Gain / power stability

±1 dB, −20 to +55°C

Cooling and mechanical integration

Request a matched drawing, mounting and cooling requirements for the agreed build and operating conditions.

Output power definition

100 W-class configuration. Supplied point tests include output below 100 W. Agree frequency-point output and operating conditions before evaluation.

Operating conditions

The supplied point-test table lists 7.7–16.1 A and does not state its supply voltage; do not treat it as a 28 V qualification.

49.6–51.9 dBm · 21 frequency points
Supplied specification point-test table, 1000–3000 MHz in 100 MHz steps; table voltage unspecified. Values below 50 dBm occur; the table does not establish guaranteed 100 W output at every frequency. Source current specification separately uses an 80 W CW condition.

Configuration reference prepared 9 November 2026. Final specifications are confirmed in the project quotation.

Website data version: web-6e71d494d838
Source / date: November 2026 specification and supplied point-test records / 2026-11-05

INTEGRATION REVIEW

Confirm the signal path before you select.

Band and power are only the first check. Agree how RF enters the assembly, how it is installed and how your controller connects.

These are document requests, not confirmed features. RS485 does not establish Modbus compatibility; alarm telemetry does not establish automatic shutdown.

web-6e71d494d838
Before you integrateThe mounting surface and coolingWatch film · 0:11

Documentation & open items

Check what this website record supports before planning a sample. Red items need matched evidence or confirmation; they are not approved specifications.

Public technical summaryAvailable

Current website record with its source, version and qualifications. This is not an approved order specification.

Download specification summary
Formal part number & hardware revisionMissing / not confirmed

Not supplied in this website record.

Matched test report & acceptance limitsPartial evidence

Point-test summaries are shown on this page. Complete test conditions and agreed acceptance limits remain unconfirmed.

Drawings, mounting & coolingMissing / not confirmed

Envelope dimensions are listed; matched mounting drawings and thermal requirements remain unconfirmed.

Pinout, drive & protection logicMissing / not confirmed

A complete matched pinout, input limits, protection actions and reset sequence remain unconfirmed.

Samples, batch delivery & warrantyMissing / not confirmed

Model- and quantity-specific sample terms, MOQ, lead-time basis and warranty require confirmation.

Review a document request

Adds these open items to the editable enquiry on this page. Nothing is submitted automatically.

ENGINEERING / PROCUREMENT

Questions about this configuration

FAQ revision: 2026-11-17.1
Website data revision — not a hardware revision: web-6e71d494d838
November 2026 specification and supplied point-test records / 2026-11-05

Does this reference cover my entire frequency interval?

The recorded interval is 1,000–3,000 MHz. Candidate screening checks whether this single reference contains both ends of your requested interval. This is a frequency check, not proof of minimum output, linearity or engineering suitability throughout that interval.

Evidence and next step
Does the 100 W class guarantee that output at every frequency?

No. The source specification uses a maximum-output definition, and the published point-test summary includes results below the class label. Point tests do not establish a full-band minimum or a continuous-duty guarantee. Review the conditions and unresolved differences before agreeing acceptance limits.

Evidence and next step
Which revision should I use when comparing files or requesting a sample?

Use website data revision web-6e71d494d838 when referring to this page. It identifies the public record, not the manufacturer's hardware or firmware revision. Confirm the formal part number and matched specification, drawing and test versions before accepting another file as a replacement.

Evidence and next step
Are drive, control and cooling requirements confirmed for this module?

Use only the fields and conditions shown for this reference. Missing drive, connector, cooling, protocol or protection details remain open for review. Do not transfer a pinout, RS485 command set, input architecture or alarm/shutdown behaviour from another configuration.

Evidence and next step
How do I request the missing documents for this exact configuration?

Use the documentation requests and editable enquiry on this page. Include the configuration revision, quantity, required documents, acceptance conditions and next step. The server validates the current public version when saving the enquiry; only a successful save returns an enquiry reference.

Evidence and next step

Technical resources

RF PA technical resources

Practical RF PA guidance for OEM engineers and purchasing teams. Read the key answers openly, then request an English PDF pack for your project review.

Read the guideDownload centre

For modules, include the operating band and required output. For other RF items, describe the supply format or provide a part number.

Add technical details & review list

Technical fields are optional. Keep your original requirement below; unknowns can be confirmed with our team.

Evaluation list (1)

Evaluation list

This is a screening list, not engineering approval. Free text and attachments are preserved for human review.

1,000–3,000 MHz · 100 W Power class
Possible fit — conditions to confirmWebsite data version: web-6e71d494d838Source / date: November 2026 specification and supplied point-test records / 2026-11-05
  • Frequency range: Needs confirmation
  • Power definition: Needs confirmation
  • Operating conditions: Needs confirmation

Source maximum-output declaration. Supplied point tests include values below 50 dBm; this is not a guaranteed 100 W minimum across the band.